5000 Series

5000 Series

3-5-6-series

Standard Features Include:

  • ETL listed
  • Heavy Duty Tubular Steel Frame
  • Heavy Duty Legs
  • Durable High-gloss Powder Coated Paint
  • Stainless Steel Compartment Covers
  • Stainless Steel Combustion Chamber
  • Heating Coil Constructed of ASTM A53 Schedule 80 Steel Pipe
  • Fuel Efficient Combustion Chamber
  • Adjustable Temerature Control
  • High-limit Temerature Control
  • Waterproof Ignition Transformer
  • Pressure Relief Valve
  • Belt Driven Pump
  • Trigger Gun Control
  • Stainless Steel Float Tank
  • Low Water Shut Off Protection
  • Wire Braid Discharge Hose
  • Quick Coupled Stainless Steel Nozzles
  • Automatic Shutdown Timer
  • Watertight Electrical Panel
  • Diagnostic Control Monitoring Lights
  • Calibrated Detergent Mixing Valve
  • Fuel Water Separator
  • Electronic Ignition
  • Hour Meter
  • Soap Solenoid
  • Cad Cell Flame Sensor (oil fired units)
  • Draft Diverter

Options Include:

  • Steam Combination (Not ETL Listed)
  • Two Gun Operation
  • Single Remote Option
  • Multi – Remote (Includes first remote control and wiring for additional remote boxes)
  • Additional Multi-Remote
  • Oil Option with Tank
  • Oil Option without Tank
  • 440 Volt 3 PH
  • Clutch Option
  Model 5403 5518 5523 5530
  Flow Output (GPM)  4.0  5.0  5.0  5.0
  Pressure Ratings (PSI)  300  1800  2300  3000
Max Output Temperature  300°  210°  210°  210°
 Cleaning Comparison Index  7750  20236  22648  25866
  Motor Horsepower  2  6  8/7.5  10
 Volt  115  230  230  230
  Amp  15  30/20  30/25  30
 Phase  1  1 or 3  1 or 3  3
  Input BTU’s (Oil Fired) 726,000  487,000  487,000  487,000
  Fuel Consumption (GPH)(2) (Oil Fired)  3.11 2.09  2.09  2.09
  Burner Fuel Tank Capacity (Oil Fired)  25  25  25  25
  Stack Size (Oil Fired)  10″  10″  10″  10″
  Input BTU’s (Gas Fired)  770,000  545,000  545,000 545,000
  Fuel Consumption NG(CFH)(2) (Gas Fired)  462 327  327  327
  Fuel Consumption LP(LBH)(2) (Gas Fired)  22.92  16.23  16.23  16.23
  LP Tank Minimum Size (Gas Fired)  100#  100#  100#  100#
  Stack Size (Gas Fired)  12″  12″  12″ 12″
  Length  64″  64″  64″  64″
  Width  28″  28″  28″  28″
  Height  58″  58″  58″  58″
  Approximate Weight (LBS) 1030  1005  1060 1070
  Discharge Hose  3/8″x 50′  3/8″x 50′  3/8″x 50′  3/8″x 50′

 

  Model 5615 5622 5630
  Flow Output (GPM)  6.0  6.0  6.0
 Pressure Ratings (PSI)  1500  2200  3000
  Max Output Temperature  210°  210°  210°
  Cleaning Comparison Index  21948  26581  31039
  Motor Horsepower  6  10  15
  Volt 230 230 230
  Amp  30/20  30  35
  Phase  1 or 3   3  3
  Input BTU’s (Oil Fired)  585,000  585,000  585,000
  Fuel Consumption (GPH) (Oil Fired)  2.51  2.51  2.51
Burner Fuel Tank Capacity (Oil Fired)  25  25  25
 Stack Size (Oil Fired)  10″  10″  10″
  Input BTU’s (Gas Fired)  670,000  670,000  670,000
  Fuel Consumption NG(CFH)(2) (Gas Fired) 402  402  402
 Fuel Consumption LP (LBH)(2) (Gas Fired)  19.95  19.95  19.95
  LP Tank Minimum Size (Gas Fired)  100#  100#  100#
  Stack Size (Gas Fired)  12″  12″  12″
  Length  64″  64″  64″
  Width  28″ 28″  28″
  Height  58″  58″  58″
  Approximate Weight (LBS)  1060  1050 1000
  Discharge Hose  3/8″ x 50′  3/8″ x 50′  3/8″ x 50′

0 Comments for “5000 Series”