Standard Features Include:
- ETL listed
- Heavy Duty Tubular Steel Frame
- Heavy Duty Legs
- Durable High-gloss Powder Coated Paint
- Stainless Steel Compartment Covers
- Stainless Steel Combustion Chamber
- Heating Coil Constructed of ASTM A53 Schedule 80 Steel Pipe
- Fuel Efficient Combustion Chamber
- Adjustable Temerature Control
- High-limit Temerature Control
- Waterproof Ignition Transformer
- Pressure Relief Valve
- Belt Driven Pump
- Trigger Gun Control
- Stainless Steel Float Tank
- Low Water Shut Off Protection
- Wire Braid Discharge Hose
- Quick Coupled Stainless Steel Nozzles
- Automatic Shutdown Timer
- Watertight Electrical Panel
- Diagnostic Control Monitoring Lights
- Calibrated Detergent Mixing Valve
- Fuel Water Separator
- Electronic Ignition
- Hour Meter
- Soap Solenoid
- Cad Cell Flame Sensor (oil fired units)
- Draft Diverter
Options Include:
- Steam Combination (Not ETL Listed)
- Two Gun Operation
- Single Remote Option
- Multi – Remote (Includes first remote control and wiring for additional remote boxes)
- Additional Multi-Remote
- Oil Option with Tank
- Oil Option without Tank
- 440 Volt 3 PH
- Clutch Option
Model | 3303 | 3416 | 3423 | 3430 |
---|---|---|---|---|
Flow Output (GPM) | 3 | 4 | 4 | 4 |
Pressure Ratings (PSI) | 300 | 1600 | 2300 | 3000 |
Max Output Temperature | 300° | 210° | 210° | 210° |
Cleaning Comparison Index | 5812 | 15112 | 18118 | 20693 |
Motor Horsepower | 0.75 | 4 | 6 | 8/7.5 |
Volt | 115 | 230 | 230 | 230 |
Amp | 10 | 20/15 | 20/15 | 30/25 |
Phase | 1 | 1 or 3 | 1 or 3 | 1 or 3 |
Input BTU’s (Oil Fired) | 420,000 | 350,000 | 350,000 | 350,000 |
Fuel Consumption (GPH)(2) (Oil Fired) | 1.8 | 1.5 | 1.5 | 1.5 |
Burner Fuel Tank Capacity (Oil Fired) | 15.5 | 15.5 | 15.5 | 15.5 |
Stack Size (Oil Fired) | 8″ | 8″ | 8″ | 8″ |
Input BTU’s (Gas Fired) | 440,000 | 400,000 | 400,000 | 400,000 |
Fuel Consumption NG(CFH)(2) (Gas Fired) | 264 | 240 | 240 | 240 |
Fuel Consumption LP(LBH)(2) (Gas Fired) | 13.1 | 11.91 | 11.91 | 11.91 |
LP Tank Minimum Size (Gas Fired) | 100# | 100# | 100# | 100# |
Stack Size (Gas Fired) | 10″ | 10″ | 10″ | 10″ |
Length | 56″ | 56″ | 56″ | 56″ |
Width | 24″ | 24″ | 24″ | 24″ |
Height | 55″ | 55″ | 55″ | 55″ |
Approximate Weight (LBS) | 730 | 728 | 776 | 794 |
Discharge Hose | 3/8″x 50′ | 3/8″x 50′ | 3/8″x 50′ | 3/8″x 50′ |
Model | 3518 | 3523 | 3530 |
---|---|---|---|
Flow Output (GPM) | 5 | 5 | 5 |
Pressure Ratings (PSI) | 1800 | 2300 | 3000 |
Max Output Temperature | 210° | 210° | 210° |
Cleaning Comparison Index | 20036 | 22648 | 25866 |
Motor Horsepower | 6 | 8/7.5 | 10 |
Volt | 230 | 230 | 230 |
Amp | 30/20 | 30/25 | 30 |
Phase | 1 or 3 | 1or 3 | 3 |
Input BTU’s (Oil Fired) | 420,000 | 420,000 | 420,000 |
Fuel Consumption (GPH) (Oil Fired) | 1.8 | 1.8 | 1.8 |
Burner Fuel Tank Capacity (Oil Fired) | 15.5 | 15.5 | 15.5 |
Stack Size (Oil Fired) | 8″ | 8″ | 8″ |
Input BTU’s (Gas Fired) | 440,000 | 440,000 | 440,000 |
Fuel Consumption NG(CFH)(2) (Gas Fired) | 264 | 264 | 264 |
Fuel Consumption LP (LBH)(2) (Gas Fired) | 13.1 | 13.1 | 13.1 |
LP Tank Minimum Size (Gas Fired) | 100# | 100# | 100# |
Stack Size (Gas Fired) | 10″ | 10″ | 10″ |
Length | 56″ | 56″ | 56″ |
Width | 24″ | 24″ | 24″ |
Height | 55″ | 55″ | 55″ |
Approximate Weight (LBS) | 824 | 848 | 848 |
Discharge Hose | 3/8″ x 50′ | 3/8″ x 50′ | 3/8″ x 50′ |